Home >> Audi >> 2012 >> A7 >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating, Ventilation & Air Conditioning (Air Guide, Coolant Circuit, Display&Control Head,Additional Components) >> 87 Air Conditioning >> Additional Components For Control And Regulation >> Function Of Air Quality Sensor -G238- >> Humidity Sensor In Fresh Air Intake Duct -G657-, Checking
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Humidity Sensor In Fresh Air Intake Duct -G657-, Checking

NOTE:

The Humidity Sensor in Fresh Air intake Duct -G657- -3- needs about 2 minutes to reach its operating temperature after the ignition is switched on. During the warm-up phase, the function of the humidity sensor in fresh air intake duct is limited.

Fig 1: Air Quality Sensor And Humidity Sensor
GWWA87-10906Courtesy of AUDI OF AMERICA, LLC

The function of the Humidity Sensor in Fresh Air intake Duct -G657- can only be checked via the "Guided Fault Finding". The measured values of the Humidity Sensor in Fresh Air intake Duct -G657- are evaluated there via the "read measured values" function and are compared to the temperature and humidity measured at the component location of the Humidity Sensor in Fresh Air intake Duct -G657-. Use the Vehicle Diagnostic Tester in the "Guided Fault Finding" function.