Breaker Arm Spring Tension
Check tension with spring scale hooked over movable contact and pulled at right angle to contact. Note reading as points just start to open. On pivotless type points, no adjustment is possible (replace breaker point assembly). On pivoted type points, adjust spring tension by loosening contact spring nut and moving spring as necessary.