Ported Vacuum Switches: Operation
When the coolant temperature rises at idle to between 220°F and 230°F, the ported vacuum switch is actuated. At this time the check ball inside the valve moves up and closes off the carburetor vacuum port. The two lower ports are now connected and the higher intake manifold vacuum is applied to the distributor. Engine speed will increase about 100 RPM as an aid to engine cooling.