Power Window Master Switch
With switch removed from door, use a self powered test light or ohmmeter to perform following tests. See illustration for pin numbers.
- Clip one test lead probe on switch pin No. 3 which is grounded. With all switches in neutral position, pins No. 4 through 11 should have continuity to pin No. 3.
- Push any one or all four of the switches forward. All odd numbered pins of the switches pushed forward should lose continuity to pin No. 3.
- Push any one or all four switches rearward and all even numbered pins (4 through 11) of the switches pushed rearward should lose continuity to pin No. 3.
- Remove test lead clip from pin No. 3 and connect it to pin No. 2. With all switches in neutral position, only pin No. 1 should have continuity to pin No. 2.
- Push any one or all four switches forward and hold in that position. All odd numbered pins of switches pushed forward should have continuity to pin No. 2.
- Pull any one or all four switches rearward and hold in that position. All even numbered pins of the switches pulled rearward should have continuity to pin No. 2.
- If any one switch does not test as above, replace switch.