Electronically Controlled Feedback Carburetor System: Notes
The use of a 3-way catalyst requires precise fuel metering. To> provide precise fuel metering, the electronically controlled feedback carburetor system consists of the following components:
- Model 6500 Feedback Carburetor
- Vacuum Solenoid/Regulator
- Exhaust Gas Oxygen Sensor
- Throttle Angle Vacuum Switch (Non-Turbo)
- Cold Temperature Vacuum Switch (Non-Turbo)
- Idle/Deceleration Vacuum Switch (Turbo)
The electronically controlled feedback carburetor system has 2 modes of operation, as determined by the sensors. These are the "Closed Loop" and "Open Loop" modes.