Test Sequence III
- Set engine to 2200-2800 RPM. Reconnect control vacuum hose to vacuum gauge "T" fitting. Disconnect vacuum hose from cold temperature vacuum switch (Pink hose). Apply 4.5-5.5 in. Hg vacuum to the switch and record data.
- While covering carburetor idle air bleed hole, reduce vacuum to zero and record data as directed on test chart. See Figure. Uncover idle air bleed hole and record data.
- Return engine to idle and verify that reading is less than 0.3 volt. Turn engine off, connect vacuum hose to fittings, and reconnect all electrical leads.NOTE: Complete all data gathering procedures for TEST SEQUENCE I, II and III before performing any diagnostic/repair procedures as listed under COMPONENT DIAGNOSIS, except as noted on data chart.