Continuous Monitor (Wiggle) Test Procedure
NOTE:
Make sure that Self-Test is deactivated. DO NOT
activate Self-Test unless specifically instructed to do so.
- This test monitors ECA inputs for shorts and opens. Self-Test Output (STO) will be activated each time a fault is detected. If the STO is activated for long enough during KEY ON/ENGINE OFF SELF-TEST portion of test, a service code will be stored. During the Engine Running Portion of this test, a service code will be stored for each fault.
- A detected fault is indicated by a 10.5 volt or greater deflection on VOPM. One or both of the following modes may be used to find the intermittent fault.
- Key On/Engine Off (KOEO): Self-Test deactivate the ignition switch ON.
- Key On/Engine Running (KOER): Self-Test activated. Perform KOER Self-Test. After service code output has finished, do not turn engine off or deactivate Self-Test. About 2 minutes after code 11 has been displayed. Continuous Monitor (Wiggle) Test mode will start. The system will remain in Continuous Monitor mode until Self-Test is deactivated or engine is turned off.NOTE: An alternate method of entering Continuous Monitor (Wiggle) mode with engine running is to start Engine Running test, exit, and reenter Engine Running test without turning engine off.
- Observe VOM while moving, wiggling, and tapping the system harness, connectors, and sensors. If an intermittent condition is created, the monitor will indicate this by storing a service code.
- Perform KOEO Self-Test to retrieve codes. If any codes are indicated, go to proper test as shown in Continuous Test table. If no codes appear, the fault is not in a monitored EEC sensor circuit. EEC testing is complete. Refer to Diagnosis By Symptom Test for additional testing information.
NOTE:
Continuous test can only be run once without turning ignition off. DO NOT
miss any of the service codes.