LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 1989 >> Bronco II RWD, Standard, M5OD-R1 >> Repair and Diagnosis >> Engine Performance >> Ignition System >> Adjustments >> Ignition Timing - Computed Timing
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Ignition Timing - Computed Timing

  1. Ensure ignition is OFF. Wait 10 seconds then activate KEY ON ENGINE RUNNING (KOER) SELF-TEST. For KOER SELF-TEST see the appropriate TESTS W/CODES article in the ENGINE PERFORMANCE section. Start engine and check computed timing after the last service code has been displayed.
  2. The timing will remain fixed for 2 minutes unless SELF-TEST is deactivated. Computed timing is equal to the base timing plus 17-23 degrees BTDC. If computed timing is not within specifications, see appropriate TESTS W/CODES article in the ENGINE PERFORMANCE section.