Test 17, A/C Pressure Switch Ground Check
Turn ignition on. Turn A/C and blower off. Disconnect A/C pressure switch connector. Using a jumper wire, jumper Blue/Green wire in connector to ground. If cooling fan runs, go to TEST 18 . If cooling fan does not run, go to TEST 19 .