Test 3, Check Pip At EDIS Module
Turn key off. Connect EDIS diagnostic cable to breakout box. Using EDIS No. 6 overlay. Connect LED test lamp between J43 (PIP E) and J7 (GND). Crank engine. If LED blinks continuously, go to TEST 4. If light does not blink, go to TEST 7.