Test DF: Step 90
90) Continuous Memory Code 22: Operate MAP/BP Sensor. Continuous Code 22 indicates the MAP/BP sensor was out of Self-Test range (1.4-1.6 volts) during normal driving conditions. Possible causes for this code are:
- Faulty MAP/BP sensor
- Faulty wiring harness or connectors
- Unusually high or low barometric pressure.
In KOEO Continuous Monitor Mode (Wiggle Test), observe test equipment while performing the following:
- Connect a vacuum pump to the MAP/BP sensor
- Slowly apply 25 in. Hg to sensor
- Slowly bleed off vacuum from sensor
- Lightly tap on sensor (to simulate road shock)
- Wiggle sensor connector