Test J: Step 92
92) Check For Shorts to Power With KOEO, breakout box installed and ECA disconnected, connect a test light between test pin No. 8 (No. 19 on 5.0L MA PFI) and test pin No. 40. Observe test light, perform WIGGLE test on FPM circuit and POWER-to-PUMP circuit. Lightly tap the fuel pump relay to simulate road shock. If light goes on to indicate a fault is found, isolate and repair as necessary. Remove test set-up and rerun QUICK TEST. If no faults are found, fault is intermittent and cannot be duplicated at this time. Clear Continuous Memory Codes and rerun QUICK TEST.