Solenoid Valve (SV) Check At ABS Control Module
- Turn ignition off. Disconnect ABS control module. Set VOM on 200 ohm scale.
- At ABS control module, measure and record resistance between following wires:
- Green/Red wire and Black/White wire.
- Green/Red wire and Blue wire.
- Green/Red wire and Blue/Orange wire.
- Green.
- If resistances are about 3 ohms, go to PINPOINT TESTS HSI-1 and HSI-2 . If resistances are not as specified, go to PINPOINT TEST SV-4 .