Vane Air Meter - 2.2L
Disconnect negative battery cable. Disconnect airflow meter electrical connector. Remove air duct from air filter cover. Remove air filter cover attaching bolts and cover. Remove vane airflow meter attaching nuts from inside air cleaner cover. Remove airflow meter. To install, reverse removal procedure.