Db-5 Continuity To Ground

Ensure ignition is off. Set ohmmeter to 200-ohm scale. Measure resistance between ABS control unit Red/Yellow and ground. If resistance is less than 100 ohms, replace ABS control unit. If resistance is greater than 100 ohms, go to DB-6 CONTINUITY TO HYDRAULIC CONTROL UNIT  .