Test SCG - Solenoid Controlled By Ground

NOTE: Enter this test only when Code 25, 26, 28, 29, 34, 41 or 42 is displayed during SELF-TEST procedures. This test is intended to diagnose the following switches and circuits: Canister Purge (CANP), EGR Control (EGRC), Fuel Pressure Regulator Control (PRC), High Inlet Air Control (HSIA), Idle Speed Control (ISC) and Turbo Boost Solenoid (BOOST).
Fig 1: Identifying Solenoid Connector Terminals
G91J08147
CIRCUIT PIN IDENTIFICATION (SCG)

Circuit Breakout Box Pin ECA Pin
CANP (1.8L & 2.2L) 31 2O, (1) 2X
EGRC (2.2L Turbo) 52 3P
PRC (1.8L & 2.2L) (1) 11, 21 (1) 2T, 3M
HSIA (1.8L) 53 2S
ISC (1.8L & 2.2L) 41 (1) 2W, 3Q
BOOST (2.2L Turbo) 35 3R
(1) Available on 1.8L and 2.2L MTX models only.

1) Checking System Integrity  Visually check all wiring, connectors and components for damage, shorting or looseness. If a fault is found, repair as necessary. If no fault is found, go to step 2).

2) Solenoid Function  Install breakout box, leaving ECA disconnected. Check function of appropriate solenoid. See SWITCH PERFORMANCE CHECK.

3)  If solenoid is okay, test is complete. If solenoid is not okay, remove connector and turn ignition on. Measure voltage between connector VPWR terminal and ground.

4)  If voltage is less than 10 volts, repair VPWR circuit. If voltage is more than 10 volts, simulate ECA solenoid activation. See SIMULATED ECA SOLENOID ACTIVATION.

5)  Measure voltage between connector VPWR terminal and SIG terminal. If voltage is more than 10 volts only when solenoid is activated, replace solenoid. If voltage is not more than 10 volts when solenoid is activated, disconnect solenoid connector.

6)  Check for continuity between breakout box test pin SIG and solenoid SIG terminal. If continuity is not present, repair SIG circuit between solenoid and ECA. If continuity exists, check for continuity between breakout box test pin SIG and all other test pins.

7)  If SIG circuit is shorted to any other circuit, repair as necessary. If SIG circuit is not shorted to any other circuit and no other problem or code are found, replace ECA.