ARW-3 Resistance At Abs Control Unit
Ensure ignition is off. Set ohmmeter to 2000-ohm scale. Measure resistance between ABS control unit terminal 2H (Green wire) and terminal 2J (Blue wire), and between ABS control unit terminal 2E (Yellow/Green wire) and terminal 2F (Yellow/Blue wire). Resistance should be 800-1200 ohms. If resistance is correct, go to ARW-5 SIGNAL AT ABS CONTROL UNIT . If resistance is not correct, go to ARW-4 RESISTANCE AT SENSOR .