LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 1992 >> Festiva GL, Standard >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes >> Pinpoint Tests >> Pinpoint Test Vat - Vane Air Temperature Sensor
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Pinpoint Test Vat - Vane Air Temperature Sensor

NOTE: Enter this test only when a Code 10 is displayed during QUICK TESTS procedure or when directed here from another PINPOINT TEST. Ambient temperature must be higher than 50°F (10°C) for this test.
Fig 1: Identifying VAT Circuits
G92C25207
VAT CIRCUIT PIN IDENTIFICATION

Circuit ECA Pin BOB Pin Wire Color
1.3L
GND 2A 46, 49 BLK
VAT 2P 45 GRN/BLK
1.6L
SIGRTN 2C 46,49 BLU/YEL
VAT 2J 25 BRN/YEL
  1. Turn ignition off. Ensure engine is at operating temperature. With ignition off, install BOB. Turn ignition on. Measure temperature near VAT sensor. Measure voltage between VAT and SIGRTN test pins. Compare voltage to specifications shown in VAT SENSOR VOLTAGE  table. If voltage is within specification, VAT circuit is okay. If voltage is not within specification, go to next step.
    VAT SENSOR VOLTAGE

    Temperature °F (°C) (1) Volts
    20 (-6) 3.64
    30 (-1) 3.36
    40 (4) 3.05
    44 (7) 2.79
    50 (10) 2.29
    60 (16) 2.61
    70 (21) 2.35
    80 (27) 2.05
    90 (32) 1.76
    100 (38) 1.57
    (1) Values may vary by 15 percent.
  2. Turn ignition off. Disconnect ECA. Measure resistance between VAT and SIGRTN test pins. Measure temperature near VAF meter. Compare resistance to specifications shown in VAT SENSOR RESISTANCE  table. If resistance is within specification, go to next step. If resistance is not within specification, go to step 4).
  3. Unplug VAF sensor connector. Measure resistance between VAT test pin and all other test pins. If any resistance is less than 5 ohms, repair VAT wire from ECA to VAF meter. If all measurements are greater than 5 ohms, replace ECA.
  4. Turn ignition off. Unplug VAF meter connector. Monitor temperature near VAT sensor. Measure resistance between VAF meter VAT and SIGRTN terminals. Compare resistance to specifications shown in VAT SENSOR RESISTANCE  table while heating VAT sensor . If resistance is within specification, repair VAT and/or SIGRTN wires from VAF to ECA. If resistance is not within specification, replace VAF meter.
VAT SENSOR RESISTANCE

Temperature °F (°C) Ohms
-4 (-23) 15,000
32 (0) 5210
68 (20) 2500
104 (40) 1100
140 (60) 600
176 (80) 300