Resistance Check
- Turn ignition off. Disconnect ABS fail-safe relay. Set VOM on 200 ohm scale. Measure resistance at ABS fail-safe relay between terminal "d" (Black/Blue wire) and terminal "e" (Black/Green wire). See Fig 1 .
- If resistance is 60-100 ohms, go to PINPOINT TEST FSR-7 . If resistance is not as specified, replace ABS fail-safe relay.