Circuit Test BP - Barometric Pressure Sensor
NOTE:
Enter this test only when Code 14 is displayed during self-test procedures (KOEO or KOER), or when directed here from another CIRCUIT TEST. To prevent unnecessary replacement of components, check for fault in the following non-EEC items: atmospheric barometer reading (unusually high or low), vacuum lines (blocked) and basic mechanical engine components.
Visually check all wiring, connectors and components for evidence of damage, shorting or looseness. If a fault is found, repair as necessary. If no fault is found, erase codes from memory. Perform KOEO and KOER self-tests. See QUICK TEST. If Code 14 continues to appear, replace ECA.
NOTE:
The barometric pressure sensor is built into the ECA and cannot be replace separately. If Code 14 appears repeatedly after clearing codes, replace ECA.