PRC Control Module Power
Disconnect PRC control module connector. Turn ignition on. Set VOM on 20-volt scale. Measure voltage between Black/Yellow wire and ground. If voltage reading is greater than 10 volts, proceed to PINPOINT TEST Q3. If voltage reading is 10 volts or less, check 15-amp fuse or repair Black/Yellow wire between PRC control module and interior fuse box.