Motor Relay Check
Disconnect ABS fail-safe relay. Set VOM on 200 ohm scale. Using jumper wire at ABS fail-safe relay, apply 12 volts from terminal "h" to terminal "j". Using VOM, measure resistance between terminal "c" and terminal "g". If resistance is less than 5 ohms, service Black/Blue wire and/or Blue/Black wire between ABS fail-safe relay and ABS control module. If resistance is greater than 5 ohms, replace ABS fail-safe relay.