LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 1992 >> Probe GL, Standard >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes - EEC-IV >> Circuit Tests >> Circuit Test TG - Electronic Transmission Continuous Memory Service Codes >> All Models
April 5, 2026: LEMON Manuals is launched! Read the announcement.

All Models

After completing appropriate DRIVE CYCLE TEST, perform KOEO and CONTINUOUS MEMORY CODE SELF-TEST. If Code 99/624, 67/634 or 651 is present, go to step 92). If none of these codes are present but Code 29/452 is present, go to CIRCUIT TEST DP for all other models. If Code 11/111 is present, fault cannot be duplicated at this time.

92) Code 99/624, 67/634 Or 651  Code 99/624 and 651 indicate Electronic Pressure Control (EPC) failure. Code 67/634 indicates that Manual Lever Position (MLP) sensor is out of calibration. Possible causes for these faults are:

Turn ignition off. Disconnect 60-pin ECA connector. Inspect terminals, and repair if damaged. Install EEC-IV Breakout Box (T83L-50-EEC-IV). Connect ECA to breakout box. To test EPC solenoid, connect DVOM to EPC test pin and EPC VPWR test pin at breakout box. To test MLP sensor, connect DVOM to MLP test pin and test pin No. 46 at breakout box. For EPC solenoid and MLP sensor, turn ignition on. Voltage for EPC should be less than 10 volts. Voltage for MLP should be less than 5 volts. Shake and bend EPC/MLP wiring harness. Lightly tap on components to simulate road shock. Voltage should remain stable. If voltage changes or exceeds specification, fault in circuit is indicated. If fault is indicated, isolate and repair as necessary. Clear continuous memory codes, and repeat QUICK TEST  . If no faults are found, problem cannot be located at this time.

93) Check Circuit Harness & Connectors  Shake and bend EEC-IV wiring harness. Lightly tap on components to simulate road shock. Perform KOEO Continuous Monitor Mode. See CIRCUIT TEST KOEO CONTINUOUS MEMORY CODES  . If fault is indicated, isolate and repair as necessary. Clear continuous memory codes, and repeat QUICK TEST  . If no faults are found, problem cannot be located at this time.

CIRCUIT TEST KOEO CONTINUOUS MEMORY CODES

Code Fault
49/617 1 - 2 Shift Incorrect
56/637 Excessive TOT Circuit Voltage
59/618 2 - 3 Shift Incorrect
66/638 Inadequate TOT Circuit Voltage
69/628 2 - 3 Shift Incorrect
619 3 - 4 Shift Incorrect
645 Inadequate 1st Gear Command Response
646 Inadequate 2nd Gear Command Response
647 Inadequate 3rd Gear Command Response
648 Inadequate 4th Gear Command Response
656 Continuous Slippage Detected