Motor Relay Operation Check
- Turn ignition off. Disconnect ABS control module. Turn ignition on. At ABS control module, connect Blue/Black wire to ground. Connect Blue/Orange wire to ground for no longer than 2 SECONDS. See Figure .
- If motor relay clicks and motor operates when Blue/Black wire is momentarily grounded, go to PINPOINT TEST MMR-10 . If motor relay clicks, but motor does not operate, go to PINPOINT TEST MMR-7 . If motor relay does not click and motor does not operate, go to PINPOINT TEST MMR-4 .