Barometric Pressure (BARO) Sensor
This unit is part of PCM, and cannot be checked or serviced. If a Code 14 is set and cannot be cleared, replace PCM.
BAROMETRIC PRESSURE SENSOR OUTPUT VOLTAGE
| Vacuum - In. Hg |
Volts |
| 0 |
3.84 |
| 5 |
3.36 |
| 10 |
2.66 |
| 15 |
1.93 |
| 20 |
1.26 |
| 25 |
0.58 |