Halogen Leak Detector

Leak Detector:





The procedure for using an electronic leak detector is similar to the procedure for flame-type leak detectors, except that the presence of refrigerant is indicated by an audible tone or flashing light. Refer to operating instructions for unit being used, and observe the following procedures:
1. Move detector probe one inch per second along areas of suspected leakage.
2. Position probe under area to be tested, as refrigerant is heavier than air.
3. Check gauge manifold, hoses and service ports for leakage.