LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 1994 >> Probe Base, Automatic >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Overhaul - Cd4E >> On-Vehicle Service >> Valve Body/Thermostatic Oil Level Control Valve >> Installation
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Valve Body/Thermostatic Oil Level Control Valve: Installation

  1. Install thermostatic oil level control valve in transaxle case. Install bracket. Tighten retaining bolt to specification. See TORQUE SPECIFICATIONS  . Install new "O" ring on valve body harness connector receptacle. Install receptacle in transaxle case.
  2. Insert "Z" link into end of manual valve. Place valve body in position on transaxle case and install 12 valve body bolts. Tighten bolts in sequence. See Figure . Tighten bolts to specification.
  3. Remove manual control lever bolt and lever assembly. Using Shifter Shaft Alignment Tool (T94P-77000-H), move manual control lever shaft to "D" position. Install pin to hold tool in position. Move manual valve detent lever assembly to "D" position. See Figure .
  4. Loosen nut on ball stud of manual valve detent lever actuating rod assembly. Snug nut on ball stud. Remove shifter pin. Rotate Shifter Shaft Alignment tool until socket can be installed on nut. Tighten bolt to specification.
  5. Rotate lever back to "D" position and recheck adjustment. Remove pin and alignment tool. Install manual control lever assembly. Tighten bolt to specification. Install main control cover (side cover) with new gasket. Tighten bolts in sequence. See Figure . Tighten bolts to specification.
  6. To complete installation, reverse removal procedures. Tighten drain plug to specification. Add 6 qts. of ATF fluid. Start and run vehicle. Add fluid as necessary.