Manual Lever Position (MLP) Sensor/Switch: Cd4E
Remove nut securing Manual Lever Position (MLP) sensor to manual lever. Turn manual lever to neutral position. Loosen bolts securing MLP sensor to transaxle. Using Adjuster (T92P-70010-AH), align MLP sensor slots. Tighten MLP sensor mounting bolts. Install manual lever retaining nut. Tighten nut to specification. See TORQUE SPECIFICATIONS table. Test sensor operation.
NOTE:
Probe models equipped with 4EAT transaxle use MLP switch instead of MLP sensor.