Hood Switch

Using a digital volt-ohmmeter, measure resistance between pins No. 5 and 23/26 (ground) of control module. Resistance should be more than 25,000 ohms with hood closed, and less than 200 ohms with hood open. If resistance is not to specification, replace hood switch and/or repair circuits No. 23 and/or No. 26