Power Door Lock
NOTE:
Do not hold power and ground to the power door lock actuator for more than five seconds at a time.
Apply 12 volts to the Red wire terminal and ground to the Green wire terminal of the door lock actuator. Reverse the connections. The actuator should produce a clicking noise when power and ground is applied in both directions. If the actuator does not click, replace the front door latch. Otherwise, return to the PINPOINT TEST .