Battery Saver & One-Touch Down Relay
Remove battery saver relay or one-touch down relay from relay module located behind center of instrument panel. Check continuity using an ohmmeter. Continuity should exist between relay terminals No. 1 and 2, and also between terminals No. 3 and 4. See Fig 1 . Using fused jumper wires, connect battery terminals to relay te rminals No. 1 and 2. Continuity should now exist between relay terminals No. 3 and 5. Replace relay if continuity is not as specified.