Clearing Diagnostic Trouble Codes
- Connect New Generation Star (NGS) scan tester on Data Link Connector (DLC) and perform proper hook-up procedure. See EQUIPMENT HOOK-UP .NOTE: If instructed to clear Diagnostic Trouble Codes (DTCs) from a specified test procedure, ensure ignition is in proper position as listed in test procedure or the test will fail.
- Turn ignition switch to RUN position unless otherwise instructed by specified test procedure. Rotate dial on scan tester to DIAGNOSTIC DATA LINK menu and press trigger.
- Rotate dial on scan tester to highlight the desired module you wish to access. Ensure DIAGNOSTIC TEST MODES is highlighted and press trigger.
- Rotate dial on scan tester to highlight RETRIEVE/CLEAR CONTINUOUS DTC and press trigger. Press button No. 3 to start.
- To clear an individual DTC from a selected module, rotate dial on scan tool to highlight the DTC to be cleared. Press button No. 8. This will clear only that DTC from that module.
- To clear all DTCs from a selected module, press button No. 7. This clears all DTCs from that module.