Window Is Stuck Or Binding
- Remove trim panel at suspect window. Actuate power window switch for down operation. Observe glass in guides. If there are no obstructions in glass guides, go to next step. If obstructions are observed, clear obstructions and lubricate glass guides. Retest system.
- Window Regulator Operation Check
Actuate power window switch for up operation. Observe window motion. If regulator does not skip or bind, go to next step. If regulator skips or binds, loosen glass guide retaining screws and adjust glass guides as necessary. Retest system.
- Regulator & Power Window Motor Check