Amperage Output Test

WARNING: This page is about a different car, the 1997 Lincoln Mark VIII. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ensure drive belt is in good condition and properly tightened. Connect charging system load tester in accordance with manufacturer's instructions. Start and run engine at 2000-3000 RPM and apply load until generator output levels off.
  2. Record maximum generator output current. See GENERATOR OUTPUT SPECIFICATIONS TABLE for output values. If generator output is 10- 20 percent of rated output amperage, generator output is okay. If generator does not produce rated output, go to VOLTAGE OUTPUT TEST .
GENERATOR OUTPUT SPECIFICATIONS

Application Amps Rating
Mark VIII 120