LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 1997 >> Windstar Base, 3.8 4 >> Repair and Diagnosis >> Body & Frame >> Body, Cab Control Systems >> Module Communications Network System >> Testing >> Test F: Air Bag Diagnostic Monitor Not Responding To Scan Tool
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Test F: Air Bag Diagnostic Monitor Not Responding To Scan Tool

  1. Check Circuit No. 70

    Disconnect air bag diagnostic monitor harness connector. Measure resistance of circuit No. 70 (Light Blue/White wire) between DLC terminal No. 7 and air bag diagnostic monitor connector terminal No. 12. See Figure. If resistance is less than 5 ohms, go to next step. If resistance is greater than 5 ohms, repair open circuit No. 70 (Light Blue/White wire). Repeat DATA LINK DIAGNOSTICS under COMMUNICATION NETWORK DIAGNOSTICS  to confirm repair.
  2. Check Diagnostic Monitor Connector

    Inspect air bag diagnostic monitor harness connector for damage or corrosion. Repair if necessary. If connector is okay, replace air bag diagnostic monitor. Repeat DATA LINK DIAGNOSTICS under COMMUNICATION NETWORK DIAGNOSTICS  to confirm repair.