Key Programming - New Key
- Connect New Generation Star (NGS) tester to Data Link Connector (DLC). Insert unprogrammed key in ignition and turn to RUN position. Wait for theft warning indicator to go out (about 2 seconds), then flash rapidly. Select PATS module on NGS.
- Select IGNITION KEY - CODE ERASE FUNCTION test (press TRIGGER twice). TEST IN PROGRESS will be displayed on screen. After 8 minutes, TEST COMPLETE will be displayed on screen. All keys are now erased. Turn key off, then to RUN position. Wait for theft warning indicator to go out (about 2 seconds). PATS key is now programmed. To program additional keys, see KEY PROGRAMMING - SPARE KEY.