Data Link Diagnostic Test
NOTE:
When performing Data Link Diagnostic Test, the NGS tester may display BUS circuits 4-PB9 and 5-PB9 as circuits No. 914 and 915. The NGS tester may also display ISO circuit 8-CF29 as circuit No. 70.
- Connect New Generation Star (NGS) tester to Data Link Connector (DLC), if not already connected. Select vehicle to be tested from NGS tester menu.
- Turn ignition on. Rotate dial on NGS tester to menu item DIAGNOSTIC DATA LINK and press trigger. A test will be performed on the BUS (circuits 4-PB9 and 5-PB9) for the module communications network and the ISO 9141 communication link (circuit 8-CF29).
- If NGS tester displays CKT 4-PB9 (+) = SYSTEM PASSED and CKT 5-PB9 (-) = SYSTEM PASSED, module communications network is okay. If NGS tester displays CKT 8-CF29 = SYSTEM PASSED, ISO 9141 communication link is operating properly. Return to article that directed you here and continue diagnosis.
- If NGS tester does not display CKT 4-PB9 (+) = SYSTEM PASSED, CKT 5-PB9 (-) = SYSTEM PASSED and CKT 8-CF29 = SYSTEM PASSED, perform the following as applicable.
- If no response from NGS tester, go to TEST F: NO MODULE/NETWORK COMMUNICATION under TESTING.
- If NGS tester displays CKT 70 = 00000001, go to TEST A: ANTI-LOCK BRAKE SYSTEM (ABS) MODULE DOES NOT RESPOND TO NGS TESTER under TESTING.
- If NGS tester displays CKT 914 = 00000003, go to TEST E: NO MODULE/NETWORK COMMUNICATION - BUS LINK under TESTING.
- If NGS tester displays CKT 915 = 00000003, go to TEST E: NO MODULE/NETWORK COMMUNICATION - BUS LINK under TESTING.
- If module in question is NO RESPONSE/NOT EQUIPPED, go to SYMPTOM INDEX table to continue diagnosis.
- If module in question is NO RESPONSE ON CKT 914 (BUS +), go to SYMPTOM INDEX table to continue diagnosis.
- If module in question is NO RESPONSE ON CKT 915 (BUS -), go to SYMPTOM INDEX table To continue diagnosis.