Key Programming - Using 2 Programmed Keys
- Insert the first programmed ignition key into ignition lock cylinder. Turn ignition switch from LOCK to RUN position (ignition switch must stay in RUN position for one second). Turn ignition switch to LOCK position and remove ignition key from ignition lock cylinder.
- Within 5 seconds of turning ignition switch to LOCK position, insert second programmed ignition key into ignition lock cylinder. Turn ignition switch from LOCK to RUN position (ignition switch must stay in RUN position for one second). Turn ignition switch to LOCK position and remove second ignition key from ignition lock cylinder.
- Within 10 seconds of turning ignition switch to LOCK position, insert a NEW unprogrammed ignition key into ignition lock cylinder. Turn ignition switch from LOCK to RUN position (ignition switch must stay in RUN position for one second). Turn ignition switch to LOCK position and remove ignition key from ignition lock cylinder. The NEW ignition key should now be programmed. To program additional key(s), repeat key programming procedure from step 1).
NOTE:
NGS tester will only store module configuration information for 24 hours.