Instrument Cluster
The instrument cluster is on the high speed CAN. It is an analog face cluster with a digital odometer. The instrument cluster displays a variety of information. If one of the bus wires becomes shorted to ground or voltage, communications can continue at a reduced level. Check the high speed CAN circuits 1908 (WH) and 1909 (BK) between the instrument cluster C220 and the DLC C251. Total resistance values must not be more than 5 ohms. If the resistance is more than 5 ohms, there is an open circuit in the CAN, damage to the DLC C251, damage to the instrument cluster C220, or a problem in the in-line connector. Since both the PCM and the instrument cluster share network termination responsibilities, a problem in either of these modules can result in a high speed CAN failure. For additional instrument cluster information, refer to INSTRUMENT CLUSTER .