Electronic Leak Detection Procedure

WARNING: This page is about a different car, the 2004 Lincoln LS. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: Good ventilation is necessary in the area where electronic A/C leak testing is to be carried out. If the surrounding air is contaminated with refrigerant gas, the leak detector will indicate this gas all the time. Odors from other chemicals such as antifreeze, diesel fuel, disc brake cleaner, or other cleaning solvents can cause the same problem. A fan, even in a well-ventilated area, is very helpful in removing small traces of contamination from the air that might affect the leak detector.
    NOTE: The system pressure should be between 413-551 kPa (60-80 psi) at 24°C (75°F) with the engine off.
    Fig 1: Inspecting Leak In Refrigerant System Using Refrigerant Leak Detector
    G03202337Courtesy of FORD MOTOR CO.
  1. Leak test the refrigerant system using the Refrigerant Leak Detector. Follow the instructions included with the leak detector for handling and operation techniques.
  2. If a leak is found, discharge and recover the refrigerant. For additional information, refer to AIR CONDITIONING (A/C) SYSTEM RECOVERY, EVACUATION AND CHARGING .
    • Repair the system.
    • Test the system for normal operation.
    Fig 2: Repairing Leak
    G03202338Courtesy of FORD MOTOR CO.