| C1779 |
(Single-zone EMTC only) Blower request signal circuit short to ground |
Go To PINPOINT TEST L: THE BLOWER MOTOR DOES NOT OPERATE CORRECTLY - EMTC . |
| B2175 |
(Single-zone EMTC only) A/C request signal circuit short to ground |
Go To PINPOINT TEST I: THE AIR CONDITIONING (A/C) IS ALWAYS ON . |
| B2513 |
Blower motor relay circuit short to ground |
EMTC and blower is inoperative, Go To PINPOINT TEST K: THE BLOWER MOTOR IS INOPERATIVE - EMTC . EMTC and blower operates, Go To PINPOINT TEST L: THE BLOWER MOTOR DOES NOT OPERATE CORRECTLY - EMTC EATC and blower is inoperative, Go To PINPOINT TEST M: THE BLOWER MOTOR IS INOPERATIVE - EATC . EATC and blower operates, Go To PINPOINT TEST N: THE BLOWER MOTOR DOES NOT OPERATE CORRECTLY - EATC . |
| B2514 |
Blower motor relay circuit open/short to voltage |
EMTC, Go To PINPOINT TEST K: THE BLOWER MOTOR IS INOPERATIVE - EMTC . EATC, Go To PINPOINT TEST M: THE BLOWER MOTOR IS INOPERATIVE - EATC . |
| B2543 |
Auxiliary control/actuator reference circuit short to ground |
If auxiliary blower, temperature and mode are all affected, Go To PINPOINT TEST O: THE AUXILIARY BLOWER MOTOR IS INOPERATIVE . If temperature only is affected, Go To PINPOINT TEST Q: THE AUXILIARY TEMPERATURE CONTROL ONLY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY . If mode only is affected, Go To PINPOINT TEST R: THE AUXILIARY PANEL/FLOOR CONTROL ONLY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY . |
| B2544 |
Auxiliary control/actuator reference circuit short to voltage |
If auxiliary blower, temperature and mode are all affected, Go To PINPOINT TEST P: THE AUXILIARY BLOWER MOTOR DOES NOT OPERATE CORRECTLY . If temperature only is affected, Go To PINPOINT TEST Q: THE AUXILIARY TEMPERATURE CONTROL ONLY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY . If mode only is affected, Go To PINPOINT TEST R: THE AUXILIARY PANEL/FLOOR CONTROL ONLY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY . |
| B2559 |
Auxiliary blower motor relay circuit short to voltage |
Go To PINPOINT TEST O: THE AUXILIARY BLOWER MOTOR IS INOPERATIVE . |
| B2688 |
Auxiliary blower motor relay circuit open/short to ground |
If auxiliary blower motor is inoperative, Go To PINPOINT TEST O: THE AUXILIARY BLOWER MOTOR IS INOPERATIVE . If auxiliary blower motor operates, Go To PINPOINT TEST P: THE AUXILIARY BLOWER MOTOR DOES NOT OPERATE CORRECTLY . |
| B2561 |
Auxiliary blower motor speed relay 1 circuit short to voltage |
Go To PINPOINT TEST P: THE AUXILIARY BLOWER MOTOR DOES NOT OPERATE CORRECTLY . |
| B2562 |
Auxiliary blower motor speed relay 1 circuit open/short to ground |
Go To PINPOINT TEST P: THE AUXILIARY BLOWER MOTOR DOES NOT OPERATE CORRECTLY . |
| B2563 |
Auxiliary blower motor speed relay 2 circuit short to voltage |
Go To PINPOINT TEST P: THE AUXILIARY BLOWER MOTOR DOES NOT OPERATE CORRECTLY . |
| B2564 |
Auxiliary blower motor speed relay 2 circuit open/short to ground |
Go To PINPOINT TEST P: THE AUXILIARY BLOWER MOTOR DOES NOT OPERATE CORRECTLY |
| B2916 |
Auxiliary blend door motor circuits shorted |
Go To PINPOINT TEST Q: THE AUXILIARY TEMPERATURE CONTROL ONLY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY . |
| B2917 |
Auxiliary mode door motor circuits shorted |
Go To PINPOINT TEST R: THE AUXILIARY PANEL/FLOOR CONTROL ONLY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY . |
| B2919 |
Auxiliary blower motor speed input circuit short to voltage |
Go To PINPOINT TEST P: THE AUXILIARY BLOWER MOTOR DOES NOT OPERATE CORRECTLY . |
| B2920 |
Auxiliary mode door feedback circuit open/shorted |
Go To PINPOINT TEST R: THE AUXILIARY PANEL/FLOOR CONTROL ONLY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY . |
| B2921 |
Auxiliary blend door feedback circuit open/shorted |
Go To PINPOINT TEST Q: THE AUXILIARY TEMPERATURE CONTROL ONLY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY . |