Symptom Chart

WARNING: This page is about a different car, the 2004 Mercury Monterey and 2004 Ford Freestar. However, it is still accessible from the selected car via links, so may be relevant.
SYMPTOM CHART

Condition Possible Sources Action
  • No communication with the electronic automatic temperature control (EATC) module
  • Circuitry short/open.
  • EATC module communication network.
  • The EATC system is inoperative, intermittent or incorrect operation
  • Circuitry short/open.
  • Input sensor (s)/erratic input signals.
  • Automatic temperature control aspirator hose and elbow.
  • Incorrect/erratic direction of airflow from outlets
  • Circuitry short/open.
  • Door actuator.
  • Mode door binding or stuck.
  • EMTC module or EATC module
  • Door actuator arm not connected to the door crank.
  • Insufficient, erratic, or no heat
  • Low engine coolant level.
  • Engine overheating.
  • Plugged or partially plugged heater core.
  • Temperature blend door is binding or stuck.
  • Temperature blend door actuator.
  • Heater hose is kinked or binding.
  • The A/C is inoperative/does not operate correctly
  • Open fuse.
  • Circuitry short/open.
  • A/C system discharged/low charge.
  • A/C pressure transducer.
  • PCM.
  • EATC module.
  • EMTC module.
  • A/C cycling switch.
  • A/C compressor clutch air gap.
  • A/C clutch relay.
  • The A/C is always on
  • Circuitry short/open.
  • EATC module.
  • EMTC module.
  • PCM.
  • A/C compressor clutch air gap.
  • A/C clutch relay.
  • The temperature control is inoperative/does not operate correctly
  • Circuitry open/shorted.
  • EMTC module.
  • EATC module.
  • Temperature blend door.
  • Temperature blend door actuator.
  • Door actuator arm not connected to the door crank.
  • The blower motor is inoperative - EMTC
  • Fuse.
  • Circuitry open/shorted.
  • A/C blower motor switch.
  • Blower motor relay.
  • A/C blower motor.
  • EMTC module. SJB.
  • The blower motor does not operate correctly - EMTC
  • Circuitry shorted.
  • A/C blower motor resistor.
  • A/C blower motor switch.
  • The blower motor is inoperative - EATC
  • Circuitry short/open.
  • Blower motor relay.
  • A/C blower motor.
  • EATC module.
  • SJB.
  • A/C blower motor speed control.
  • The blower motor does not operate correctly - EATC
  • Circuitry short/open.
  • A/C blower motor speed control.
  • EATC module.
  • A/C blower motor speed control.
  • The auxiliary blower motor is inoperative
  • Fuse.
  • Circuitry short/open.
  • Auxiliary blower motor resistor.
  • Auxiliary blower motor.
  • The auxiliary blower motor does not operate correctly
  • Fuse.
  • Circuitry short/open.
  • Auxiliary blower motor relay.
  • Auxiliary blower motor speed relay 1.
  • Auxiliary blower motor speed relay 2.
  • Rear auxiliary control.
  • Auxiliary blower motor resistor.
  • The auxiliary temperature control only is inoperative/does not operate correctly
  • Fuse.
  • Circuitry short/open.
  • SJB.
  • Auxiliary blend door actuator.
  • Auxiliary blend door.
  • The auxiliary panel/floor control only is inoperative/does not operate correctly
  • Fuse.
  • Circuitry short/open.
  • SJB.
  • Auxiliary mode door actuator.
  • Auxiliary mode door.
  • The auxiliary temperature and panel/floor control is inoperative/does not operate correctly
  • Fuse.
  • Circuitry short/open.
  • Rear auxiliary control.
  • SJB.
  • Insufficient air conditioning (A/C) cooling
  • Low refrigerant level.
  • Temperature blend door actuator.
  • The dual temperature control is inoperative/does not operate correctly
  • Temperature blend door/actuator broken/binding
  • EMTC/EATC module
  • Low A/C refrigerant charge
  • Check that the A/C system pressure is above 290 kPa (42 psi). If the pressure is below 290 kPa (42 psi) refer to FLUORESCENT DYE LEAK DETECTION . CHECK the temperature blend doors/actuators for a binding or broken condition. If no condition is found, INSTALL a new EMTC/EATC module.
  • The temperature set point does not repeat after turning the ignition switch OFF
  • Open fuse.
  • Circuitry short/open.
  • EATC module.
  • CHECK circuit 1001 (WH/YE) for a short or open and repair as necessary. If okay, INSTALL a new EATC module.
  • The temperature display will not switch between Celsius and Fahrenheit
  • EATC module.
  • IC module.
  • If the instrument cluster does not switch between English and Metric, refer to INFORMATION, GAUGES & WARNING DEVICES .
  • If only the EATC module does not switch between English and Metric, INSTALL a new EATC module.