Spring Lock Coupling: Disconnect

WARNING: This page is about a different car, the 2005 Lincoln LS. However, it is still accessible from the selected car via links, so may be relevant.
  1. Remove the spring lock coupling clip, if equipped.
  2. CAUTION: Do not use metal tools to remove the O-ring seals. They can cause axial scratches across the O-ring seal grooves, resulting in refrigerant leaks.
    Fig 1: Pulling Spring Lock Coupling Fittings Apart
    G03889982Courtesy of FORD MOTOR CO.
  3. Push the tool into the cage opening to release the female fitting from the spring lock coupling spring and pull the fitting apart.
    • Remove the O-ring seals using a non-metallic tool.
  4. CAUTION: Do not use a screwdriver or similar tool to remove the A/C tube lock coupling spring; this can cause axial scratches across the O-ring seal grooves resulting in refrigerant leaks.
    Fig 2: Identifying Spring Lock Coupling Spring
    G03915811Courtesy of FORD MOTOR CO.
  5. Remove the spring lock coupling spring with a small hooked wire.