- The smart junction box (SJB) does not respond to the diagnostic tool
|
- Bussed electrical center (BEC)fuse(s):
- 58 (30A).
- 62 (30A).
- 65 (30A).
- Circuit or connection in the standard corporate protocol (SCP) communication network.
- SJB.
|
|
- The driver seat module (DSM) does not respond to the diagnostic tool
|
- Bussed electrical center (BEC) fuse(s):
- Circuit or connection in universal asynchronous receiver-transmitter (UART)-based protocol (UBP) network.
- DSM.
|
|
- The powertrain control module (PCM) does not respond to the diagnostic tool
|
- Circuit or connection in the standard corporate protocol (SCP) communication network.
- PCM.
|
|
- The instrument cluster does not respond to the diagnostic tool
|
- Circuit or connection in the standard corporate protocol (SCP) communication network.
- Instrument cluster.
|
|
- The restraint control module (RCM) does not respond to the diagnostic tool
|
- Circuit or connection in International Standards Organization (ISO) 9141 network.
- RCM.
|
|
- The anti-lock brake system (ABS) module does not respond to the diagnostic tool
|
- Circuit or connection in the standard corporate protocol (SCP) communication network
- ABS module.
|
|
- The dual automatic temperature control (DATC) module does not respond to the diagnostic tool
|
- Circuit or connection in the standard corporate protocol (SCP) communication network.
- DATC module.
|
|
- The speed control actuator does not respond to the diagnostic tool
|
- Circuit or connection in the standard corporate protocol (SCP) communication network.
- Speed control actuator.
|
|
- The parking aid module does not respond to the diagnostic tool
|
- Circuit or connection in International Standards Organization (ISO) 9141 network.
- Parking aid module.
|
|
- The driver/passenger climate controlled seat module does not respond to the diagnostic tool
|
- Circuit or connection in the universal asynchronous receiver-transmitter (UART)-based protocol (UBP) network.
- Driver temperature seat controlled module.
|
|
- The left hand (LH) or right hand (RH) power sliding door (PSD) module does not respond to the diagnostic tool
|
- Circuit or connection in international standards organization (ISO) 9141 network.
- RH PSD or LH PSD module.
|
|
- The power liftgate module does not respond to the diagnostic tool
|
- Circuit or connection in international standards organization (ISO) 9141 network.
- Power liftgate module.
|
|
- No universal asynchronous receiver-transmitter (UART)-based protocol (UBP) network communication
|
- Circuit or connection in UBP network.
- UBP networked modules.
|
|
- No international standards organization (ISO) 9141 network communication
|
- Circuit or connection in ISO 9141 network.
- ISO 9141 networked modules.
|
|
- No standard corporate protocol (SCP) network communication
|
- Circuit or connection in the SCP communication network.
- SCP networked modules.
|
|
- No module/network communication - no power to the diagnostic tool
|
- Smart junction box (SJB) fuse: 11 (5A).
- Data link connector (DLC) C251 pins.
- Diagnostic tool.
- Circuitry.
|
|