Pinpoint Test Pc: Run The Data Link Diagnostics Test
PC1 DATA LINK DIAGNOSTICS TEST
- Carry out the data link diagnostics test.
- Is system passed obtained?
Yes
RETURN to the Symptom Chart for the module in question.
No
If ISO circuit faults; all electronic control units no response/not equipped, Go To PINPOINT TEST G: NO INTERNATIONAL STANDARDS ORGANIZATION (ISO) 9141 NETWORK COMMUNICATION .
If SCP+ circuit faults; all electronic control units no response/not equipped, Go To PINPOINT TEST H: NO STANDARD CORPORATE PROTOCOL (SCP) NETWORK COMMUNICATION .
If SCP- circuit faults; all electronic control units no response/not equipped, Go To PINPOINT TEST H: NO STANDARD CORPORATE PROTOCOL (SCP) NETWORK COMMUNICATION .
If CAN+ circuit faults; all electronic control units no response/not equipped, Go To PINPOINT TEST I: NO CAN NETWORK COMMUNICATION - 2.3L ONLY .
If CAN- circuit faults; all electronic control units no response/not equipped, Go To PINPOINT TEST I: NO CAN NETWORK COMMUNICATION - 2.3L ONLY .
If no response from the diagnostic tool, Go To PINPOINT TEST J: NO MODULE/NETWORK COMMUNICATION .