Disassembling & Assembling
- Using a suitable torque converter fluid cooler cleaner, flush the torque converter.
- After flushing, remove the drain plug, if equipped, and drain the remainder of the solvent.
- Add 1.9 liters (2 quarts) of clean automatic transmission fluid into the torque converter and agitate by hand.
- Thoroughly drain the solution.
- If equipped, install a new torque converter drain plug.
CAUTION:
The torque converter drain plug and seal are not reusable. If equipped, discard the drain plug and seal, and install a new drain plug and seal assembly.
CAUTION:
Mineral spirits used to clean the torque converter must be fresh, non- water based, non-chlorinated and non-halogenated.