Fuel Pump Monitor (With Fuel Pump Driver Module)
Fuel Pump Driver Module (FPDM) communicates diagnostic information to PCM through Fuel Pump Monitor (FPM) circuit. This information is sent by FPDM as a duty cycle signal. The 3 duty cycle signals that may be sent are listed in FUEL PUMP DRIVER MODULE DUTY CYCLE SIGNALS table. PCM uses this signal to verify FPDM is powered and able to communicate on the FPM circuit.
FUEL PUMP DRIVER MODULE DUTY CYCLE SIGNALS
| Duty Cycle Percent |
On Time (ms) |
Comments |
FP_M PID |
| 25 |
250 |
FPDM Did Not Receive Fuel Pump (FP) Duty Cycle Command From PCM, Or Duty Cycle Received Was Invalid |
15-60 |
| 50 |
500 |
"All Ok" Output From FPDM. With This Input, PCM Can Verify FPDM Is Powered And Able To Communicate On FPM Circuit |
80-125 |
| 75 |
750 |
FPDM Has Detected Fault In Circuits Between Fuel Pump And FPDM |
250-400 |