Automatic Transmission Diagnosis DTCS
AUTOMATIC TRANSMISSION DIAGNOSTIC TROUBLE CODE (DTC) LIST
| DTC | Component | Description | Condition | Symptom | Perform Test |
|---|---|---|---|---|---|
| P1705 | TR | TR not in PARK. | Self-test not run in PARK. | Rerun self-test in PARK. | Go to PINPOINT TEST D. |
| P1747 Output circuit check, generated only by electrical symptoms. P1760 | EPC | EPC solenoid circuit failure, shorted to ground. | Voltage through EPC solenoid is checked and compared to a voltage through solenoid after a time delay. An error will be noted if tolerance is exceeded. KOEO and continuous self-test. | Short to ground: limit engine torque (partial fuel shut-off, heavy misfire). Minimum line pressure. | Go to PINPOINT TEST E. |
| P1746 Output circuit check, generated only by electrical symptoms. | EPC | Open PCM output driver. | Voltage through EPC solenoid is checked and compared to a voltage through solenoid after a time delay. An error will be noted if tolerance is exceeded. KOEO and continuous self-test. | Open circuit - causes maximum EPC pressure, harsh engagements and shifts. | Go to PINPOINT TEST E. |
| P0731 May also be generated by some other non-electric transaxle hardware system. | SSA, SSB, or internal parts | First gear failure. | No first gear. | Incorrect gear selection depending on condition mode and manual lever position: see Solenoid ON/OFF Chart. Shift errors may also be due to other internal transaxle concerns (such as stuck valves, damaged friction material). | Go to PINPOINT TEST A. |
| P0732 ay also be generated by some other non-electric transaxle hardware system. | SSA, SSB, or internal parts | Second gear failure. | No second gear. | Incorrect gear selection depending on condition mode and manual lever position: see solenoid ON/OFF Chart. Shift errors may also be due to other internal transaxle concerns (such as stuck valves, damaged friction material). | Go to PINPOINT TEST A. |
| P0733 May also be generated by some other non-electric transaxle hardware system. | SSA, SSB, or internal parts | Third gear failure. | No third gear. | Incorrect gear selection depending on condition mode and manual lever position: see solenoid ON/OFF Chart. Shift errors may also be due to other internal transaxle concerns (such as stuck valves, damaged friction material). | Go to PINPOINT TEST A. |
| P0734 May also be generated by some other non-electric transaxle hardware system. | SSA, SSB, or internal parts | Fourth gear failure. | No fourth gear. | Incorrect gear selection depending on condition mode and manual lever position: see Solenoid ON/OFF Chart. Shift errors may also be due to other internal transaxle concerns (such as stuck valves, damaged friction material). | Go to PINPOINT TEST A. |
| P0707 | TR | TR out of range. Shorted circuit or sensor. | TR sensor, circuit or powertrain control module shorted to ground. | No fourth gear operation, firm shift feel, no manual first gear. No TCC operation. | Go to PINPOINT TEST D. |
| P0708 | TR | TR out of range. Open circuit or sensor. | TR sensor, circuit or powertrain control module indicate open. | No fourth gear operation, firm shift feel, no manual first gear. | Go to PINPOINT TEST D. |
| P1789 Output circuit check, generated only by electrical symptoms. |
3-2T/CCS | 3-2T/CCS solenoid circuit failure - short. | 3-2T/CCS circuit fails to provide voltage drop across solenoid. Circuit shorted during self-test. | Failed on - no engine braking (except in OD), delayed 3-2 downshifts. | Go to PINPOINT TEST G. |
| P1788 Output circuit check, generated only by electrical symptoms. |
3-2T/CCS | 3-2T/CCS solenoid circuit failure - open. | 3-2T/CCS circuit fails to provide voltage drop across solenoid. Circuit open or processor drive circuit failure during self-test. | Failed off - engine braking in second/third gears, firm or flared 3-2 downshifts. Harsh 4-3 downshifts. | Go to PINPOINT TEST G. |
| P1742, P1743 The TCIL code will set on the first fault occurrence. On the second fault occurrence plus the second power up, the MIL and TCIL will illuminate. | TCC | TCC solenoid failed on. | TCC solenoid has failed on by electrical; mechanical or hydraulic concern. | Harsh shifts, may stall vehicle at low speeds. | Go to PINPOINT TEST C. |
| P0743 Output circuit check, generated only by electrical symptoms.P0740 The TCIL code will set on the first fault occurrence. On the second fault occurrence plus the second power up, the MIL and TCIL will illuminate. | TCC | Torque converter clutch solenoid circuit failure during self-test. | TCC solenoid circuit fails to provide voltage drop across solenoid. Circuit shorted or processor drive failure during self-test. | Failed on - engine stalls in manual second, engine lugging, poor performance at low engine speeds, harsh shifts. | Go to PINPOINT TEST C. |
| P1744, P0741 The TCIL code will set on the first fault occurrence. On the second fault occurrence plus the second power up, the MIL and TCIL will illuminate. | TCC | Excessive slip detected. | Excessive slip detected during full TCC engagement | Torque converter disengaged. EPC pressure at minimum. | Go to PINPOINT TEST C. |
| P1751 | SSA | Shift solenoid A functional failure. | Mechanical or hydraulic failure of the solenoid. | Incorrect gear selection depending on failure mode and manual lever position (TCIL flashing). | Go to PINPOINT TEST A. |
| P0750 Output circuit check, generated only by electrical symptoms. P0753. The TCIL code will set on the first fault occurrence. On the second fault occurrence plus the second power up, the MIL and TCIL will illuminate. | SSA | SSA solenoid circuit failure. | Solenoid A circuit failed to provide voltage drop across solenoid. Circuit open or shorted or processor driver failure during self-test. | Incorrect gear selection depending on condition mode and manual lever position: see Solenoid ON/OFF Chart. | Go to PINPOINT TEST A. |
| P1714 | SSA | SSA fault. | Mechanical failure of the solenoid detected. | Incorrect gear selection depending on condition, mode and manual lever position: see SOLENOID OPERATION CHART. | Go to PINPOINT TEST H. |
| P0751 | SSA | Shift solenoid A functional failure. | Mechanical or hydraulic failure of the solenoid. | Incorrect gear selection depending on failure mode and manual lever position (MIL on). | Go to PINPOINT TEST A. |
| P1715 | SSB | SSB fault. | Mechanical failure of the solenoid detected. | Incorrect gear selection depending on condition, mode and manual lever position: see SOLENOID OPERATION CHART. | Go to PINPOINT TEST H. |
| P0755. Output circuit check, generated only by electrical symptoms. P0758 . The TCIL code will set on the first fault occurrence. On the second fault occurrence plus the second power up, the MIL and TCIL will illuminate. | SSB | SSB solenoid circuit failure. | Solenoid B circuit failed to provide voltage drop across solenoid. Circuit open or shorted or processor driver failure during self-test. | Incorrect gear selection depending on condition mode and manual lever position: see Solenoid ON/OFF Chart. | Go to PINPOINT TEST A. |
| P1756 | SSB | Shift solenoid B functional failure. | Mechanical or hydraulic failure of the solenoid. | Incorrect gear selection depending on failure mode and manual lever position (TCIL flashing). | Go to PINPOINT TEST A. |
| P0756 | SSB | Shift solenoid B functional failure. | Mechanical or hydraulic failure of the solenoid. | Incorrect gear selection depending on failure mode and manual lever position (MIL on). | Go to PINPOINT TEST A. |
| P0721 | OSS | OSS signal noisy. | PCM has detected a noisy OSS sensor signal. | Harsh shifts, abnormal shift schedule operation. | Go to PINPOINT TEST F. |
| P0720 | OSS | Insufficient input from OSS sensor. | PCM has detected a loss of OSS signal during operation. | Harsh shift, abnormal shift schedule operation. | Go to PINPOINT TEST F. |
| P0722 | OSS | OSS signal intermittent. | PCM has detected an intermittent OSS signal. | Harsh shift, abnormal shift schedule operation. | Go to PINPOINT TEST F. |
| P0717 | TSS | Turbine shaft speed sensor circuit - signal. | PCM has detected NO TSS signal. | Possible harsh shifts, converter locks, or engagements. | Go to PINPOINT TEST F. |
| P0715 | TSS | Insufficient input from turbine speed sensor. | PCM detected a loss of TSS signal during operation. | No torque converter engagements or harsh shifts. No fourth gear operation and engine braking in second and third gear. | Go to PINPOINT TEST F. |
| P0718 | TSS | Turbine shaft speed sensor circuit intermittent. | PCM has detected a noisy TSS signal. | Possible harsh shifts, converter locks, or engagements. | Go to PINPOINT TEST F. |
| P1702 | TRS | Transmission range sensor circuit. | Transmission range sensor circuit intermittent. | Possible wrong gear (s) commanded. | Go to PINPOINT TEST D. |
| P1713 | TFT | Transmission fluid temperature sensor in low failure. | PCM has detected no TFT change at low TCC range during operation. | Increase EPC, incorrect engagement schedule, harsh engagement harsh shifts. | Go to PINPOINT TEST B. |
| P1711 | TFT | TFT out of ST range. | Transaxle not at operating temperature during self-test. | Warm vehicle to normal operating temperature. | Go to PINPOINT TEST B. |
| P0713 | TFT | -40°C (-40°F) indicated TFT sensor circuit open. | Voltage drop across TFT sensor exceeds scale set for temperature -40°C (-40°F). | Incorrect torque converter clutch operation. Incorrect EPC pressure control. | Go to PINPOINT TEST B. |
| P0712 | TFT | 150°C (302°F) indicated TFT sensor circuit grounded. | Voltage drop across TFT sensor exceeds temperature of 150°C (302°F). | Incorrect torque converter clutch operation. Incorrect EPC pressure control. | Go to PINPOINT TEST B. |
| P1718 | TFT | Transmission fluid temperature sensor in high failure. | PCM has detected no TFT change at high TCC range during operation. | Increase EPC, incorrect engagement schedule, harsh engagement, harsh shifts. | Go to PINPOINT TEST B. |