Pinpoint Test A: No Communication With The Abs Module
A1 CHECK CIRCUIT 15-CF6A (GN/YE) FOR AN OPEN
- Disconnect: ABS Module C135.
- Key in ON position.
- Measure the voltage between the ABS module C135 pin 4, circuit 15-CF6A (GN/YE), harness side and ground.
- Is the voltage greater than 10 volts?
Yes
Go to A2.
No
REPAIR circuit 15-CF6A (GN/YE) or 15-CF6 (GN/YE) as necessary. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
A2 CHECK CIRCUIT 91-CF6 (BK/YE) FOR AN OPEN
- Key in OFF position.
- Measure the resistance between the ABS module C135 pin 16, circuit 91-CF6 (BK/YE), harness side and ground.
- Is the resistance less than 5 ohms?
Yes
INSTALL a new ABS module. REFER to HYDRAULIC CONTROL UNIT (HCU) . REPEAT the self-test. TEST the system for normal operation.
No
REPAIR circuit 91-CF6 (BK/YE) or 91-CF1 (BK/BU) as necessary. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.