LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2005 >> Explorer Sport Trac RWD >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> Automatic Transaxle/Transmission DTCS >> 5R55E
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Automatic Transaxle/Transmission DTCS: 5R55E

DIAGNOSTIC TROUBLE CODE (DTC) LIST

DTC Component Description Condition Symptom Perform Test
P0731 May also be generated by some other non-electric transmission hardware system. SSA, SSB, SSC or Internal Parts 1st gear error No 1st gear. Incorrect gear selection depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). REFER toSOLENOID OPERATION CHARTS . Then GO to PINPOINT TEST A .
P0732 May also be generated by some other non-electric transmission hardware system. SSA, SSB, SSC or Internal Parts 2nd gear error No 2nd gear. Incorrect gear selection depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). REFER to SOLENOID OPERATION CHARTS . Then GO to PINPOINT TEST A .
P0733 May also be generated by some other non-electric transmission hardware system. SSA, SSB, SSC or Internal Parts 3rd gear error No 3rd gear. Incorrect gear selection depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). REFER to the SOLENOID OPERATION CHARTS . Then GO to PINPOINT TEST A .
P0734 May also be generated by some other non-electric transmission hardware system. SSA, SSB, SSC or Internal Parts 4th gear error No 4th gear. Incorrect gear selection depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material). REFER to SOLENOID OPERATION CHARTS . Then GO to PINPOINT TEST A .
P0750 Output circuit check, generated only by electrical symptoms. SSA SSA solenoid circuit failure SSA circuit failed to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Incorrect gear selection depending on condition mode and manual lever position. See SOLENOID OPERATION CHARTS . Will flash MIL. GO to PINPOINT TEST A .
P0753 Output circuit check, generated only by electrical symptoms. SSA SSA solenoid circuit failure SSA circuit failed to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Incorrect gear selection depending on condition mode and manual lever position. See SOLENOID OPERATION CHARTS . Will flash TCIL. GO to PINPOINT TEST A .
P0755 Output circuit check, generated only by electrical symptoms. SSB SSB solenoid circuit failure SSB circuit fails to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Incorrect gear selection depending on condition mode and manual lever position. See SOLENOID OPERATION CHARTS . Will flash MIL. GO to PINPOINT TEST A .
P0758 Output circuit check, generated only by electrical symptoms. SSB SSB solenoid circuit failure SSB circuit fails to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Incorrect gear selection depending on condition mode and manual lever position. See SOLENOID OPERATION CHARTS . Will flash TCIL. GO to PINPOINT TEST A .
P0740 TCC TCC circuit intermittent PCM has detected an intermittent TCC circuit signal. Short circuit - converter clutch always engages. Open circuit - torque converter clutch never engages. Engine rpm may be higher or lower than expected. May flash TCIL. GO to PINPOINT TEST F .
P0741 May also be generated by some other non-electric transmission hardware system. TCC TCC slippage detected The PCM picked up an excessive amount of TCC slippage during normal vehicle operation. TCC slippage/erratic or no torque converter clutch operation. Flash TCIL. REFER to DIAGNOSIS BY SYMPTOM , for diagnosing TCC concerns.
P0743 Output circuit check, generated only by electrical symptoms. TCC TCC solenoid circuit failure during on-board diagnostic TCC solenoid circuit fails to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostics. Short circuit - engine stalls in second (OD, 2 range) at low idle speeds with brake applied. Open circuit - torque converter clutch never engages. GO to PINPOINT TEST A .
P1740 TCC TCC malfunction Mechanical failure of the solenoid detected. Failed ON - engine stalls in 2nd (O/D, Manual 2 ranges) at low idle speeds with brake applied. Failed OFF - torque converter never applies. GO to PINPOINT TEST F .
P0715 TSS Insufficient input from turbine shaft speed sensor PCM detected a loss of TSS signal during operation. Harsh shifts, abnormal shift schedule, no torque converter clutch activation. GO to PINPOINT TEST E .
P0717 TSS TSS circuit intermittent PCM has detected an intermittent TSS circuit signal. Harsh shifts, abnormal shifts and no torque converter engagement. May flash TCIL. GO to PINPOINT TEST E .
P0718 TSS TSS signal noisy PCM has detected a noisy TSS signal. Harsh shifts, abnormal shifts and no torque converter engagement. May flash TCIL. GO to PINPOINT TEST E .
P0720 OSS Insufficient input from OSS sensor PCM detected a loss of OSS signal during operation. Harsh shifts, abnormal shift schedule, no torque converter clutch engagement. GO to PINPOINT TEST E .
P0721 OSS Output shaft speed sensor signal noisy PCM has detected an erratic OSS signal. Harsh shifts, abnormal shift schedule, no torque converter clutch engagement. GO to PINPOINT TEST E .
P0722 OSS OSS circuit intermittent PCM has detected an intermittent OSS circuit signal. Harsh shifts, abnormal shifts and no torque converter engagement. May flash TCIL. GO to PINPOINT TEST F .
P1711 TFT TFT out of on-board diagnostic range Transmission not at operating temperature during on-board diagnostic. DTC set - vehicle cold or overheated. Warm or cool vehicle to normal operating temperature. Then GO to PINPOINT TEST B .
P0713 TFT -40°C (-40°F) indicated TFT sensor circuit open Voltage drop across TFT sensor exceeds scale set for temperature -40°C (-40°F). Firm shift feel. GO to PINPOINT TEST B .
P0712 TFT 157°C (315°F) indicated TFT sensor circuit grounded Voltage drop across TFT sensor exceeds scale set for temperature of 157°C (315°F). Firm shift feel. GO to PINPOINT TEST B .
P1783 TFT Transmission overtemp condition indicated Transmission fluid temperature exceeded 127°C (270°F). Increase in EPC pressure. GO to PINPOINT TEST B .
P1704 Digital TR Digital TR circuits reading in-between gear positions during KOEO/KOER Digital TR sensor or shift cable incorrectly adjusted or digital TR circuit failure. Wrong commanded EPC pressure. Digital TR reading the wrong gear position, (for example, in overdrive position, transmission stuck in manual 2). GO to PINPOINT TEST C .
P1705 Digital TR Digital TR not in PARK or NEUTRAL during KOEO/KOER KOEO/KOER not run in PARK or NEUTRAL; or digital TR circuit failure. Rerun KOEO/KOER in PARK or NEUTRAL. GO to PINPOINT TEST C .
P0705 Digital TR Sensor Digital TR circuit failure Digital TR circuits, indicating an invalid pattern in TR_D. Condition caused by a short to ground or an open in TR4, TR3A, TR2 and or TR1 circuits. This DTC cannot be set by an incorrectly adjusted digital TR sensor. Increase in EPC pressure (harsh shifts). Defaults to (D) or D for all gear positions. In (D) position transmission is stuck in D or manual 2. GO to PINPOINT TEST C .
P0708 Digital TR Sensor Digital TR sensor circuit TR3A open Digital TR sensor circuit TR3A reading 2.6v - 5.0v (open circuit). This DTC cannot be set by an incorrectly adjusted digital TR sensor. Increase in EPC pressure. Defaults to (D) or D for all gear ranges. GO to PINPOINT TEST C .
P0760 Output circuit check, generated only by electrical symptoms. SSC SSC solenoid circuit failure SSC circuit failed to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Incorrect gear selection depending on condition mode and manual lever position. REFER to SOLENOID OPERATION CHART . Will flash MIL. GO to PINPOINT TEST A .
P0763 Output circuit check, generated only by electrical symptoms. SSC SSC solenoid circuit failure SSC circuit failed to provide voltage drop across solenoid. Circuit open or shorted or PCM driver failure during on-board diagnostic. Incorrect gear selection depending on condition mode and manual lever position. REFER to SOLENOID OPERATION CHART . Will flash TCIL. GO to PINPOINT TEST A .
P1714 SSA SSA malfunction Mechanical failure of the solenoid detected. Incorrect gear selection depending on condition, mode and manual lever position. REFER to SOLENOID OPERATION CHART . GO to PINPOINT TEST F .
P1715 SSB SSB malfunction Mechanical failure of the solenoid detected. Incorrect gear selection depending on condition, mode and manual lever position. REFER to SOLENOID OPERATION CHART . GO to PINPOINT TEST F .
P1716 SSC SSC malfunction Mechanical failure of the solenoid detected. Incorrect gear selection depending on condition, mode and manual lever position. REFER to SOLENOID OPERATION CHART . GO to PINPOINT TEST F .
P1717 SSD SSD malfunction Mechanical failure of the solenoid detected. Incorrect gear selection depending on condition, mode and manual lever position. REFER to SOLENOID OPERATION CHART . GO to PINPOINT TEST F .
P0735 SSA, SSB, SSC, SSD or Internal Parts 5th gear error No 5th gear. Incorrect gear selection depending on failure or mode and manual lever position. Shift errors may also be due to other internal transmission concerns (stuck valves, damaged friction material etc.). REFER to SOLENOID OPERATION CHARTS . Then GO to PINPOINT TEST A .
P0791 ISS Intermediate shaft speed sensor signal failure. PCM has detected a loss of the ISS signal. Harsh shifts (2-3). GO to PINPOINT TEST E .
P0794 ISS Intermediate shaft speed sensor signal intermittent PCM has detected an intermittent ISS signal. Harsh shifts (2-3). GO to PINPOINT TEST E .
P1636 SSx SSx ISIG communication error PCM has detected an error with the ISIG chip. - INSTALL a new PCM.
P0765 SSD SSD solenoid circuit failure SSD circuit failed to provide voltage drop across solenoid. Circuit open, shorted or PCM driver circuit failure during on-board diagnostics. Incorrect gear selection depending on condition, mode and manual lever position. REFER to the SOLENOID OPERATION CHARTS . Will flash MIL. GO to PINPOINT TEST A .
P0768 SSD SSD solenoid circuit failure SSD circuit failed to provide voltage drop across solenoid. Circuit open, shorted or PCM driver circuit failure during on-board diagnostics. Incorrect gear selection depending on condition, mode and manual lever position. REFER to the SOLENOID OPERATION CHARTS . Will flash TCIL. GO to PINPOINT TEST A .
P0960 EPC Solenoid EPC solenoid circuit failed open Voltage through EPC solenoid is checked. An error will be noted if tolerance is exceeded. Open circuit: maximum EPC pressure, harsh engagements and shifts. Will flash MIL. GO to PINPOINT TEST D .
P0962 EPC Solenoid EPC solenoid circuit failure, short to ground Voltage through EPC solenoid is checked. An error will be noted if tolerance is exceeded. Third gear only in the OD detent. No converter engagement and SSI is OFF in REVERSE. For a short to ground, circuit causes minimum EPC pressure (minimum capacity) and limits engine torque (alternate firm). Slips in gear and 3rd gear incorrect. Will flash MIL. GO to PINPOINT TEST D .
P0963 EPC Solenoid EPC solenoid short to power (Vbat) circuit failure Voltage through EPC solenoid is checked. An error will be noted if tolerance is exceeded. Maximum EPC pressure, harsh engagements and shifts. Will flash TCIL. GO to PINPOINT TEST D .
P0748 EPC Solenoid EPC solenoid circuit intermittent short to ground Voltage through EPC solenoid is checked. An error will be noted if tolerance is exceeded. Third gear only in the OD detent. No converter engagement and SSI is OFF in REVERSE. For a short to ground, circuit causes minimum EPC pressure (minimum capacity) and limits engine torque (alternate firm). Slips in gear and 3rd gear incorrect. Will flash TCIL. GO to PINPOINT TEST D .